{"id":869,"date":"2018-03-26T15:32:06","date_gmt":"2018-03-26T15:32:06","guid":{"rendered":"http:\/\/www.comvolt.com\/eblog\/?p=869"},"modified":"2018-03-26T15:32:06","modified_gmt":"2018-03-26T15:32:06","slug":"jumper-descriptions-on-little-giant-bl1100-zworld-c-programmable-controller","status":"publish","type":"post","link":"http:\/\/www.comvolt.com\/eblog\/jumper-descriptions-on-little-giant-bl1100-zworld-c-programmable-controller\/","title":{"rendered":"Jumper Descriptions on Little Giant BL1100 &#8211; ZWorld C-Programmable Controller"},"content":{"rendered":"<p>If you are doing a conversion form Zworlds little giant\u00a0BL1100, start by understanding what the jumpers are and how they are connected to your application.\u00a0 Your new design will be dependent on the settings and will likely only need a fraction of the capability of this BL1100 board.\u00a0 We have seen some applications that use most of its functionality, but it is usually just a couple of IO ports and and communications ports&#8230;<br \/>\n<a href=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting1.png\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-medium wp-image-872\" src=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting1.png?resize=201%2C300\" alt=\"\" width=\"201\" height=\"300\" srcset=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting1.png?resize=201%2C300 201w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting1.png?w=503 503w\" sizes=\"auto, (max-width: 201px) 100vw, 201px\" \/><\/a><br \/>\n<a href=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting2.png\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-medium wp-image-871\" src=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting2.png?resize=225%2C300\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting2.png?resize=225%2C300 225w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2018\/03\/jumpersetting2.png?w=547 547w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><\/p>\n<p>Table B-4. Standard BL1100 Jumper Settings<br \/>\nHeader Pins Description Factory<br \/>\nDefault<\/p>\n<p>J12<\/p>\n<p>1\u20132<\/p>\n<p>Connect for factory-default RS-232 or RS-485<br \/>\nprogramming mode, remove for run mode or<br \/>\nuser-defined programming mode<\/p>\n<p>Connected<\/p>\n<p>6\u201310<\/p>\n<p>CTC3 output drives CTC2<\/p>\n<p>8\u20139<\/p>\n<p>CTC2 output drives CTC3<\/p>\n<p>6\u201311<\/p>\n<p>CTC2 operates at 16X baud rate of z0<\/p>\n<p>6\u201312<\/p>\n<p>CTC2 operates at 16X baud rate of z1<\/p>\n<p>8\u201311<\/p>\n<p>CTC3 operates at 16X baud rate of z0<\/p>\n<p>8\u201312<\/p>\n<p>CTC3 operates at 16X baud rate of z1<\/p>\n<p>9\u201311<\/p>\n<p>CTC2 drives external clock at 1\/16 z0 baud<br \/>\nrate<\/p>\n<p>10\u201312<\/p>\n<p>CTC3 drives external clock at 1\/16 z1 baud<br \/>\nrate<\/p>\n<p>1\u20132<br \/>\nJ13<\/p>\n<p>J14<\/p>\n<p>J014<\/p>\n<p>J15<br \/>\nJ16<br \/>\nJ17<\/p>\n<p>SIO Port A to RS-232 (J8)<\/p>\n<p>Connected<\/p>\n<p>2\u20133<\/p>\n<p>SIO Port A to RS-485 (J3)<\/p>\n<p>3\u20134<\/p>\n<p>ZIO Port 1 to RS-485 (J3)<\/p>\n<p>1\u20134<\/p>\n<p>ZIO Port 1 to RS-232 (J8)<\/p>\n<p>1\u20132<\/p>\n<p>SIO Port A to RS-485 (J3)<\/p>\n<p>2\u20133<\/p>\n<p>ZIO Port 1 to RS-485 (J3)<\/p>\n<p>Connected<\/p>\n<p>1\u20132<\/p>\n<p>RX and TX clocks come from SIO<\/p>\n<p>Connected<\/p>\n<p>2\u20134<\/p>\n<p>TX clock from SIO, RX clock from external<br \/>\nsource via pins 3\u20134 of header J3\/J301<\/p>\n<p>1\u20132<\/p>\n<p>SRAM smaller than 256K<\/p>\n<p>2\u20133<\/p>\n<p>SRAM 256K or larger<\/p>\n<p>1\u20132<\/p>\n<p>EPROM 32 K<\/p>\n<p>2\u20134<\/p>\n<p>EPROM larger than 32K<\/p>\n<p>1\u20132<\/p>\n<p>Connect to enable excitation resistors for<br \/>\nanalog input signal conditioning op-amps<\/p>\n<p>Connected<\/p>\n<p>Connected<br \/>\nConnected<br \/>\nNot<br \/>\nconnected<\/p>\n<p>continued\u2026<\/p>\n<p>\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd<\/p>\n<p>\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd<\/p>\n<p>Table B-4. Standard BL1100 Jumper Settings (concluded)<br \/>\nHeader<\/p>\n<p>Pins<\/p>\n<p>1\u20132<br \/>\nJ18<\/p>\n<p>Factory<br \/>\nDefault<\/p>\n<p>Description<\/p>\n<p>RS-485 three-state always enabled<\/p>\n<p>Connected<\/p>\n<p>2\u20133<\/p>\n<p>RS-485 three-state controlled by PB0<\/p>\n<p>none<\/p>\n<p>RS-485 three-state always disabled<\/p>\n<p>1\u20132<\/p>\n<p>Connect to enable onboard +5 V power<br \/>\nsupply, disconnect for external power supply<\/p>\n<p>Connected<\/p>\n<p>1\u20132<\/p>\n<p>EPROM smaller than 256K<\/p>\n<p>Connected<\/p>\n<p>2\u20134<\/p>\n<p>EPROM 256K<\/p>\n<p>1\u20132<\/p>\n<p>Write-protect upper part of EEPROM<\/p>\n<p>2\u20133<\/p>\n<p>Write-enable upper part of EEPROM<\/p>\n<p>J22<\/p>\n<p>1\u20132<\/p>\n<p>Connect to enable watchdog timer<\/p>\n<p>Not<br \/>\nconnected<\/p>\n<p>J25<\/p>\n<p>1\u20132<\/p>\n<p>Startup mode factory-default RS-232 or read<br \/>\nfrom EEPROM<\/p>\n<p>Connected<\/p>\n<p>1\u20132<\/p>\n<p>Remote reset using RXC<\/p>\n<p>2\u20133<\/p>\n<p>Remote reset using CTSB<\/p>\n<p>none<\/p>\n<p>No remote reset<\/p>\n<p>1\u20132<\/p>\n<p>Connect to enable switching power supply,<br \/>\ndisconnect for time\/date clock to control<br \/>\npower supply<\/p>\n<p>1\u20132<\/p>\n<p>Output DAC to pin 1 on J5\/J501<\/p>\n<p>2\u20133<\/p>\n<p>Pin 1 of J5\/J501 is analog ground<\/p>\n<p>1\u20132<\/p>\n<p>Connects E to expansion bus J24 pin 52<\/p>\n<p>2\u20133<\/p>\n<p>Connects BATACT to expansion bus J24 pin<br \/>\n52<\/p>\n<p>J31<\/p>\n<p>1\u20132<\/p>\n<p>Ties high-voltage driver SUB signal to ground<br \/>\nto keep it from floating<\/p>\n<p>Connected<\/p>\n<p>J32<\/p>\n<p>1\u20132<\/p>\n<p>Connect to control use of ENMI signal on<br \/>\nexpansion bus J24 pin 9<\/p>\n<p>Connected<\/p>\n<p>J19<br \/>\nJ20<br \/>\nJ21<\/p>\n<p>J26<\/p>\n<p>J27<\/p>\n<p>J28<\/p>\n<p>J29<\/p>\n<p>\ufffd\ufffd\ufffd\ufffd\ufffd\ufffd<\/p>\n<p>Connected<\/p>\n<p>Not<br \/>\ninstalled<\/p>\n<p>Connected<\/p>\n<p>Connected<br \/>\nNot<br \/>\ninstalled<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you are doing a conversion form Zworlds little giant\u00a0BL1100, start by understanding what the jumpers are and how they are connected to your application.\u00a0 Your new design will be dependent on the settings and will likely only need a &hellip; <a href=\"http:\/\/www.comvolt.com\/eblog\/jumper-descriptions-on-little-giant-bl1100-zworld-c-programmable-controller\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1],"tags":[515,513,517,523,514,524,518,516,519,520,522,521,512],"class_list":["post-869","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-baud","tag-bl110","tag-clock","tag-eprom","tag-jumpers","tag-little-giant","tag-port","tag-rate","tag-rs485","tag-rx","tag-stram","tag-tx","tag-zworld"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/869","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/comments?post=869"}],"version-history":[{"count":3,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/869\/revisions"}],"predecessor-version":[{"id":875,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/869\/revisions\/875"}],"wp:attachment":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/media?parent=869"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/categories?post=869"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/tags?post=869"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}