{"id":318,"date":"2016-09-01T15:19:16","date_gmt":"2016-09-01T15:19:16","guid":{"rendered":"http:\/\/www.comvolt.com\/eblog\/?p=318"},"modified":"2017-09-01T15:05:37","modified_gmt":"2017-09-01T15:05:37","slug":"kla-therma-wave-backplane-connector-on-14-008473-rev-b-14-007009-rev-b1-rev-g-14-007003","status":"publish","type":"post","link":"http:\/\/www.comvolt.com\/eblog\/kla-therma-wave-backplane-connector-on-14-008473-rev-b-14-007009-rev-b1-rev-g-14-007003\/","title":{"rendered":"KLA Therma-Wave Opti-Probe 14-008473 REV B 14-007009 REV B1 REV G 14-007003 Backplane Connector on"},"content":{"rendered":"<p>If you get your electronics from <a href=\"http:\/\/www.getspares.com\">GetSpares.com<\/a>, you know the unit will be fully functional.\u00a0 Why?\u00a0 Because they test it in the actual tool and run wafers.\u00a0 Once in a while, a fully functional board can get damaged due to a simple installation mishap.\u00a0 This post describes this exact situation on KLA \/ Thermawave Opti-Probe 2600,2690,3260 and 3290 series film measurement tools. Some common revs of this board have part numbers:<\/p>\n<p>14-008473, 14-007009, 14-007003,\u00a0 14-010064<\/p>\n<p>A 2 minute card swap can turn into a disaster if the P1 power connector is installed 180 degrees rotated.\u00a0 Careful, this is easy to do because the connector is not keyed!\u00a0 Take a look at the following picture to see the correct orientation.<\/p>\n<div id=\"attachment_323\" style=\"width: 594px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.comvolt.com\/eblog\/kla-therma-wave-backplane-connector-on-14-008473-rev-b-14-007009-rev-b1-rev-g-14-007003\/august-31-2016-125641-pm-cdt\/\" rel=\"attachment wp-att-323\"><img data-recalc-dims=\"1\" decoding=\"async\" aria-describedby=\"caption-attachment-323\" loading=\"lazy\" class=\"size-large wp-image-323\" src=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?resize=584%2C704\" alt=\"P1 Connector. Pin 1 location\" width=\"584\" height=\"704\" srcset=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?resize=850%2C1024 850w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?resize=249%2C300 249w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?resize=768%2C926 768w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?w=1699 1699w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/August-31-2016-125641-PM-CDT.jpg?w=1168 1168w\" sizes=\"auto, (max-width: 584px) 100vw, 584px\" \/><\/a><p id=\"caption-attachment-323\" class=\"wp-caption-text\">P1 Connector. Pin 1 location<\/p><\/div>\n<div id=\"attachment_321\" style=\"width: 594px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.comvolt.com\/eblog\/kla-therma-wave-backplane-connector-on-14-008473-rev-b-14-007009-rev-b1-rev-g-14-007003\/thermawave_panels\/\" rel=\"attachment wp-att-321\"><img data-recalc-dims=\"1\" decoding=\"async\" aria-describedby=\"caption-attachment-321\" loading=\"lazy\" class=\"size-large wp-image-321\" src=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?resize=584%2C460\" alt=\"Applies to 2600,2680,3260,3290\" width=\"584\" height=\"460\" srcset=\"https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?resize=1024%2C806 1024w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?resize=300%2C236 300w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?resize=768%2C604 768w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?resize=381%2C300 381w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?w=1168 1168w, https:\/\/i0.wp.com\/www.comvolt.com\/eblog\/wp-content\/uploads\/2016\/08\/Thermawave_panels.jpg?w=1752 1752w\" sizes=\"auto, (max-width: 584px) 100vw, 584px\" \/><\/a><p id=\"caption-attachment-321\" class=\"wp-caption-text\">Applies to 2600,2680,3260,3290<\/p><\/div>\n<p class=\"it-ttl\">\u00a0What happens if it rotated?\u00a0 More than we have time to describe!\u00a0 But basically, when this board fails you may see the following errors:<\/p>\n<p class=\"it-ttl\">0x09080008 Can&#8217;t complete hardware initialization<\/p>\n<p class=\"it-ttl\">0x0608000A Can&#8217;t Focus<\/p>\n<p class=\"it-ttl\">0x06080011 Failed to close high mag focus loop<\/p>\n<p class=\"it-ttl\">0x06080035 High mag focus capture failed: soft limit<\/p>\n<p class=\"it-ttl\">0x06080050 Focus pos: 5.466 Limit: 5.465 Corr: 0.000<\/p>\n<p class=\"it-ttl\">Don&#8217;t forget to visit <a href=\"http:\/\/www.getspares.com\">GetSpares.com<\/a> for this auto-focus board and many other semiconductor parts.<\/p>\n<p class=\"it-ttl\">Hope this helps and Good luck!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you get your electronics from GetSpares.com, you know the unit will be fully functional.\u00a0 Why?\u00a0 Because they test it in the actual tool and run wafers.\u00a0 Once in a while, a fully functional board can get damaged due to &hellip; <a href=\"http:\/\/www.comvolt.com\/eblog\/kla-therma-wave-backplane-connector-on-14-008473-rev-b-14-007009-rev-b1-rev-g-14-007003\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[144,125],"tags":[360,361,362,363,359,344,341,339,427,335,336,337,338,345,349,357,347,350,346,75,353,355,354,131,356,351,333,348,227,340,342,343,358,334,352],"class_list":["post-318","post","type-post","status-publish","format-standard","hentry","category-mapping","category-metrology","tag-0x0608000a","tag-0x06080011","tag-0x06080035","tag-0x06080050","tag-0x09080008","tag-14-007003","tag-14-007009","tag-14-008473","tag-14-010064","tag-335","tag-336","tag-337","tag-338","tag-auto","tag-back-plane","tag-capture","tag-error","tag-film","tag-focus","tag-getspares","tag-hardware","tag-high-mag","tag-initialization","tag-kla","tag-loop","tag-measurement","tag-opti-probe","tag-p1","tag-pcb","tag-rev-b","tag-rev-b1","tag-rev-g","tag-soft-limit","tag-therma-wave","tag-tools"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/318","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/comments?post=318"}],"version-history":[{"count":10,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/318\/revisions"}],"predecessor-version":[{"id":413,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/posts\/318\/revisions\/413"}],"wp:attachment":[{"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/media?parent=318"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/categories?post=318"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.comvolt.com\/eblog\/wp-json\/wp\/v2\/tags?post=318"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}